AC DC Configurable Power Supply Chassis
|
|
Mfr Part #
|
Quantity Available
|
Price
|
Product Status
|
User Configuration
|
Type
|
Number of Positions
|
Voltage - Input
|
Power (Watts)
|
Voltage - Isolation
|
Efficiency
|
Features
|
Operating Temperature
|
Size / Dimension
|
Height
|
Approval Agency
|
Standard Number
|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
4509 In Stock |
282.26000 |
Active |
- |
Medical |
4 |
85 ~ 264 VAC, 120 ~ 380 VDC |
600 W |
4 kV |
91% |
Conformal Coating, Fan Fail, Reverse Fan, Ruggedized, Temperature Alarm |
-40°C ~ 70°C (With Derating) |
10.24" L x 3.50" W (260.0mm x 89.0mm) |
1.59" (40.40mm) |
CE |
- |
||
1708 In Stock |
319.06000 |
Active |
- |
Medical |
6 |
85 ~ 264 VAC |
1200 W |
4 kV |
90% |
Fan Fail, Temperature Alarm |
-40°C ~ 70°C (With Derating) |
10.24" L x 5.00" W (260.0mm x 127.0mm) |
1.59" (40.40mm) |
CE |
- |
||
18 In Stock |
315.32000 |
Active |
- |
Medical |
4 |
85 ~ 264 VAC |
600 W |
4 kV |
94% |
- |
-40°C ~ 85°C (With Derating) |
8.50" L x 4.50" W (215.9mm x 114.3mm) |
1.50" (38.1mm) |
CE |
- |
||
3286 In Stock |
264.95000 |
Active |
- |
Medical |
4 |
85 ~ 264 VAC |
600 W |
4 kV |
90% |
Fan Fail, Temperature Alarm |
-40°C ~ 70°C (With Derating) |
10.24" L x 3.50" W (260.0mm x 89.0mm) |
1.59" (40.40mm) |
CE, cURus |
- |
||
19 In Stock |
527.10000 |
Active |
- |
Medical, Low Noise |
6 |
85 ~ 264 VAC |
1200 W |
4 kV |
90% |
Fan Fail, Temperature Alarm |
-20°C ~ 70°C (With Derating) |
10.24" L x 5.00" W (260.0mm x 127.0mm) |
1.59" (40.40mm) |
CE, cURus |
- |
||
15 In Stock |
755.68000 |
Active |
- |
Standard |
6 |
85 ~ 264 VAC |
1000 W |
3 kV |
90% |
- |
-55°C ~ 70°C (With Derating) |
10.55" L x 5.00" W (268.0mm x 127.0mm) |
1.00" (25.4mm) |
CE |
- |
||
20 In Stock |
504.24000 |
Active |
- |
Medical, Low Noise |
6 |
85 ~ 264 VAC |
900 W |
4 kV |
90% |
Fan Fail, Temperature Alarm |
-20°C ~ 70°C (With Derating) |
10.24" L x 5.00" W (260.0mm x 127.0mm) |
1.59" (40.40mm) |
CE, cURus |
- |
||
15 In Stock |
502.02000 |
Active |
- |
Medical |
6 |
85 ~ 264 VAC |
1200 W |
4 kV |
90% |
Fan Fail, Temperature Alarm |
-20°C ~ 70°C (With Derating) |
10.24" L x 5.00" W (260.0mm x 127.0mm) |
1.59" (40.40mm) |
CE, cURus |
- |
||
14 In Stock |
299.79000 |
Active |
- |
Standard, Low Noise |
4 |
85 ~ 264 VAC |
400 W |
3 kV |
89% |
Fan Fail, Temperature Alarm |
-20°C ~ 70°C (With Derating) |
10.24" L x 3.50" W (260.0mm x 89.0mm) |
1.59" (40.40mm) |
CE, cURus |
- |
||
1 In Stock |
431.21000 |
Active |
- |
Standard, Low Noise |
6 |
85 ~ 264 VAC |
900 W |
3 kV |
90% |
Fan Fail, Temperature Alarm |
-20°C ~ 70°C (With Derating) |
10.24" L x 5.00" W (260.0mm x 127.0mm) |
1.59" (40.40mm) |
CE, cURus |
- |
||
5 In Stock |
648.73000 |
Active |
- |
Standard |
6 |
85 ~ 264 VAC |
1000 W |
3 kV |
90% |
- |
-40°C ~ 70°C (With Derating) |
10.55" L x 5.00" W (268.0mm x 127.0mm) |
1.00" (25.4mm) |
CE |
- |
||
10 In Stock |
458.99000 |
Active |
- |
Standard |
6 |
85 ~ 264 VAC |
1340 W |
3 kV |
90% |
Fan Fail, Temperature Alarm |
-20°C ~ 70°C (With Derating) |
10.55" L x 5.00" W (268.0mm x 127.0mm) |
1.59" (40.40mm) |
CE, cURus |
- |
||
2 In Stock |
783.12000 |
Obsolete |
- |
Standard |
6 |
85 ~ 264 VAC |
1600 W |
4.24 kV |
86% |
- |
-20°C ~ 70°C (With Derating) |
11.13" L x 5.00" W (282.8mm x 127.0mm) |
1.60" (40.64mm) |
CE, cCSAus, NEMKO |
- |
||
7455 In Stock |
223.36600 |
Active |
- |
Medical |
4 |
85 ~ 264 VAC |
600 W |
4 kV |
90% |
Ruggedized |
-40°C ~ 70°C (With Derating) |
10.24" L x 3.50" W (260.0mm x 89.0mm) |
1.59" (40.40mm) |
CE, cURus |
- |
||
1425 In Stock |
301.71000 |
Active |
- |
Medical |
4 |
85 ~ 264 VAC |
600 W |
4 kV |
89% |
Fan Fail, Temperature Alarm |
-20°C ~ 70°C (With Derating) |
10.24" L x 3.50" W (260.0mm x 89.0mm) |
1.59" (40.40mm) |
CE, cURus |
- |
||
5 In Stock |
340.42000 |
Active |
- |
Standard, Ultra Quiet |
4 |
85 ~ 264 VAC, 120 ~ 380 VDC |
200 W |
3 kV |
89% |
Conformal Coating, Fan Fail, Reverse Fan, Ruggedized, Temperature Alarm |
-20°C ~ 70°C (With Derating) |
10.24" L x 3.50" W (260.0mm x 89.0mm) |
1.59" (40.40mm) |
CE, cURus |
- |
||
9173 In Stock |
235.55000 |
Active |
- |
Medical |
4 |
85 ~ 264 VAC |
600 W |
4 kV |
90% |
Conformal Coating, Ruggedized |
-40°C ~ 70°C (With Derating) |
10.24" L x 3.50" W (260.0mm x 89.0mm) |
1.59" (40.40mm) |
CE, cURus |
- |
||
8382 In Stock |
260.64000 |
Active |
- |
Medical |
4 |
85 ~ 264 VAC |
600 W |
4 kV |
90% |
Fan Fail, Temperature Alarm |
-40°C ~ 70°C (With Derating) |
10.24" L x 3.50" W (260.0mm x 89.0mm) |
1.59" (40.40mm) |
CE, cURus |
- |
||
45 In Stock |
532.90000 |
Active |
- |
Medical |
6 |
85 ~ 264 VAC |
1340 W |
4 kV |
90% |
Fan Fail, Temperature Alarm |
-20°C ~ 70°C (With Derating) |
10.55" L x 5.00" W (268.0mm x 127.0mm) |
1.59" (40.40mm) |
CE, cURus |
- |
||
8858 In Stock |
254.30000 |
Active |
- |
Standard |
4 |
85 ~ 264 VAC, 120 ~ 380 VDC |
400 W |
3 kV |
89% |
Conformal Coating, Fan Fail, Reverse Fan, Ruggedized, Temperature Alarm |
-20°C ~ 70°C (With Derating) |
10.24" L x 3.50" W (260.0mm x 89.0mm) |
1.59" (40.40mm) |
CE, cURus |
- |
||
6100 In Stock |
324.01000 |
Active |
- |
Standard |
4 |
85 ~ 264 VAC |
750 W |
4 kV |
90% |
Fan Fail, Temperature Alarm |
-20°C ~ 70°C (With Derating) |
10.55" L x 3.50" W (268.0mm x 89.0mm) |
1.59" (40.40mm) |
CE, cURus |
- |
||
8557 In Stock |
292.39000 |
Active |
- |
Medical |
4 |
85 ~ 264 VAC |
400 W |
4 kV |
89% |
Fan Fail, Temperature Alarm |
-20°C ~ 70°C (With Derating) |
10.24" L x 3.50" W (260.0mm x 89.0mm) |
1.59" (40.40mm) |
CE, cURus |
- |
||
2707 In Stock |
331.95000 |
Active |
- |
Medical, Low Noise |
4 |
85 ~ 264 VAC |
400 W |
4 kV |
89% |
Fan Fail, Temperature Alarm |
-20°C ~ 70°C (With Derating) |
10.24" L x 3.50" W (260.0mm x 89.0mm) |
1.59" (40.40mm) |
CE, cURus |
- |
||
7476 In Stock |
291.27000 |
Active |
- |
Medical |
4 |
85 ~ 264 VAC |
600 W |
4 kV |
89% |
Fan Fail, Temperature Alarm |
-20°C ~ 70°C (With Derating) |
10.24" L x 3.50" W (260.0mm x 89.0mm) |
1.59" (40.40mm) |
CE, cURus |
- |