AC DC Converters
|
|
Mfr Part #
|
Quantity Available
|
Price
|
Product Status
|
Type
|
Number of Outputs
|
Voltage - Input
|
Voltage - Output 1
|
Voltage - Output 2
|
Voltage - Output 3
|
Voltage - Output 4
|
Current - Output (Max)
|
Power (Watts)
|
Applications
|
Features
|
Operating Temperature
|
Efficiency
|
Mounting Type
|
Package / Case
|
Size / Dimension
|
Approval Agency
|
Standard Number
|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
200 In Stock |
20.20000 |
Active |
- |
- |
85 ~ 305 VAC, 120 ~ 430 VDC |
12V |
- |
- |
- |
4.166A |
- |
- |
- |
- |
79% |
- |
- |
2.83" L x 1.97" W x 0.98" H (72.0mm x 50.0mm x 25.0mm) |
- |
- |
||
1532 In Stock |
75.17950 |
Not For New Designs |
Enclosed |
1 |
85 ~ 264 VAC |
48V |
- |
- |
- |
1.25A |
60 W |
ITE (Commercial) |
Universal Input |
-10°C ~ 70°C (With Derating) |
84% |
Through Hole |
6-DIP Module, 4 Leads |
3.50" L x 2.66" W x 1.35" H (88.9mm x 67.5mm x 34.2mm) |
CE, UL |
60950-1 |
||
200 In Stock |
54.10000 |
Active |
- |
- |
85 ~ 305 VAC, 120 ~ 430 VDC |
48V |
- |
- |
- |
2.083A |
- |
- |
- |
- |
85% |
- |
- |
3.00" L x 3.00" W x 1.06" H (76.2mm x 76.2mm x 27.0mm) |
- |
- |
||
5977 In Stock |
13.24000 |
Active |
Open Frame |
1 |
90 ~ 264 VAC, 120 ~ 370 VDC |
5V |
- |
- |
- |
2A |
10 W |
Household Appliances, ITE (Commercial) |
Universal Input |
-40°C ~ 75°C (With Derating) |
80% |
Through Hole |
4-DIP Module |
1.50" L x 1.00" W x 0.85" H (38.1mm x 25.4mm x 21.5mm) |
CB Scheme, EN, FCC, IEC, UL |
55024; 55032 Class A; 60950-1; 61000-3-2; 61000-3-3; 61000-6-1; 61000-6-3; 61000-6-4; 61204-3; 62368-1 |
||
3803 In Stock |
128.62000 |
Active |
Enclosed |
1 |
90 ~ 264 VAC |
48V |
- |
- |
- |
2.08A |
100 W |
Medical |
Adjustable Output, PFC, Remote On/Off, Universal Input |
-30°C ~ 70°C (With Derating) |
90% |
Through Hole |
7-DIP Module |
3.30" L x 2.30" W x 1.38" H (83.9mm x 58.5mm x 35.0mm) |
CE, cURus, UKCA |
60601-1 |
||
9525 In Stock |
28.18300 |
Active |
Enclosed |
1 |
85 ~ 264 VAC |
3.3V |
- |
- |
- |
4.1A |
20 W |
ITE (Commercial) |
Universal Input |
-40°C ~ 70°C (With Derating) |
73% |
Through Hole |
6-DIP Module |
2.75" L x 1.89" W x 0.94" H (70.0mm x 48.0mm x 24.0mm) |
CB Scheme, EN, IEC, UL |
55024; 55032 Class A; 60950-1; 61000-3-2; 61000-3-3 |
||
4500 In Stock |
34.16000 |
Active |
Open Frame |
1 |
85 ~ 264 VAC |
15V |
- |
- |
- |
1A |
15 W |
Medical |
Universal Input |
-20°C ~ 70°C (With Derating) |
80% |
Through Hole |
4-DIP Module |
2.44" L x 1.21" W x 0.96" H (62.0mm x 30.7mm x 24.4mm) |
CE, cULus, TUV |
60601-1 |
||
5466 In Stock |
38.54750 |
Active |
Enclosed |
1 |
90 ~ 264 VAC |
5V |
- |
- |
- |
8A |
60 W |
ITE (Commercial) |
Universal Input |
-30°C ~ 70°C (With Derating) |
86% |
Through Hole |
6-DIP Module |
2.14" L x 2.14" W x 1.41" H (54.3mm x 54.3mm x 35.8mm) |
CE, cURus, FCC, Nemko |
62368-1 |
||
6877 In Stock |
13.80000 |
Active |
Enclosed |
1 |
90 ~ 264 VAC, 120 ~ 370 VDC |
5V |
- |
- |
- |
2A |
10 W |
Household Appliances, ITE (Commercial) |
Universal Input |
-40°C ~ 75°C (With Derating) |
80% |
Through Hole |
4-DIP Module |
1.60" L x 1.10" W x 0.77" H (40.6mm x 27.9mm x 19.6mm) |
CB Scheme, EN, FCC, IEC, UL |
55024; 55032 Class A; 60950-1; 61000-3-2; 61000-3-3; 61000-6-1; 61000-6-3; 61000-6-4; 61204-3; 62368-1 |
||
22 In Stock |
15.77000 |
Active |
Enclosed |
1 |
90 ~ 264 VAC, 120 ~ 370 VDC |
15V |
- |
- |
- |
333mA |
5 W |
ITE (Commercial) |
Universal Input |
-25°C ~ 70°C (With Derating) |
83% |
Through Hole |
5-DIP Module |
1.00" L x 1.00" W x 0.63" H (25.4mm x 25.4mm x 16.1mm) |
cURus, UL |
60950-1; 62368-1 |
||
8073 In Stock |
13.70000 |
Active |
Open Frame |
1 |
85 ~ 264 VAC |
5V |
- |
- |
- |
2.8A |
15 W |
ITE (Commercial) |
Universal Input |
-25°C ~ 70°C (With Derating) |
81.37% |
Through Hole |
4-DIP Module |
2.33" L x 1.67" W x 0.90" H (59.2mm x 42.3mm x 22.9mm) |
CB Scheme, EN, FCC, IEC, UL |
60950-1; 61000-3-2; 61000-3-3; 62368-1 |
||
18 In Stock |
18.23000 |
Active |
Open Frame |
1 |
90 ~ 264 VAC, 120 ~ 370 VDC |
36V |
- |
- |
- |
1.39A |
50 W |
Household Appliances, ITE (Commercial) |
Adjustable Output, Universal Input |
-30°C ~ 80°C (With Derating) |
89% |
Through Hole |
6-DIP Module |
3.00" L x 2.00" W x 1.14" H (76.2mm x 50.8mm x 29.0mm) |
CE, cURus, FCC |
60335-1; 62368-1 |
||
11 In Stock |
44.78000 |
Active |
Open Frame |
3 |
85 ~ 264 VAC |
5V |
15V |
-15V |
- |
2A, 150mA, 150mA |
15 W |
ITE (Commercial) |
Universal Input |
-20°C ~ 70°C (With Derating) |
81% |
Through Hole |
7-DIP Module |
2.44" L x 1.21" W x 0.96" H (62.0mm x 30.7mm x 24.4mm) |
CSA, cUL, EN, IEC, UL |
62368-1 |
||
9122 In Stock |
999.00000 |
Active |
Enclosed |
1 |
85 ~ 264 VAC, 120 ~ 370 VDC |
15V |
- |
- |
- |
2A |
30 W |
ITE (Commercial), Medical |
Adjustable Output, Universal Input |
-40°C ~ 85°C (With Derating) |
90.5% |
Through Hole |
5-DIP Module |
2.89" L x 1.50" W x 1.00" H (73.3mm x 38.1mm x 25.4mm) |
CB, CE, cURus, FCC |
- |
||
431 In Stock |
44.35000 |
Active |
Open Frame |
1 |
85 ~ 264 VAC |
12V |
- |
- |
- |
2.5A |
30 W |
Medical |
Universal Input |
-20°C ~ 70°C (With Derating) |
80% |
Through Hole |
4-DIP Module |
2.96" L x 1.36" W x 1.05" H (75.2mm x 34.6mm x 26.7mm) |
CB, TUV, UL |
60601-1 |
||
48 In Stock |
11.42000 |
Active |
Enclosed |
1 |
85 ~ 264 VAC |
24V |
- |
- |
- |
250mA |
6 W |
ITE (Commercial) |
Universal Input |
-25°C ~ 70°C (With Derating) |
79.03% |
Through Hole |
4-DIP Module |
2.00" L x 1.00" W x 0.66" H (50.8mm x 25.4mm x 16.7mm) |
CB Scheme, EN, FCC, IEC, UL |
60950-1; 61000-3-2; 61000-3-3; 62368-1 |
||
4999 In Stock |
21.38450 |
Active |
Enclosed |
2 |
85 ~ 264 VAC, 120 ~ 370 VDC |
12V |
-12V |
- |
- |
166mA, 166mA |
4 W |
ITE (Commercial) |
Universal Input |
-25°C ~ 60°C (With Derating) |
77% |
Through Hole |
7-DIP Module |
1.44" L x 1.06" W x 0.67" H (36.5mm x 27.0mm x 17.1mm) |
CE, UL |
60950-1 |
||
10 In Stock |
170.00000 |
Obsolete |
Enclosed |
1 |
90 ~ 264 VAC |
24V |
- |
- |
- |
4.2A |
101 W |
ITE (Commercial) |
Baseplate, PFC, Universal Input |
-20°C ~ 85°C (With Derating) |
91% |
Through Hole |
Module |
4.60" L x 2.40" W x 0.67" H (116.8mm x 61.0mm x 17.0mm) |
CE, cURus, FCC, TUV |
60950-1 |
||
2 In Stock |
68.85000 |
Active |
Enclosed |
1 |
85 ~ 264 VAC, 120 ~ 370 VDC |
3.3V |
- |
- |
- |
10A |
40 W |
ITE (Commercial) |
Universal Input |
-25°C ~ 70°C (With Derating) |
73% |
Through Hole |
4-DIP Module |
3.10" L x 1.50" W x 1.10" H (78.7mm x 38.1mm x 27.9mm) |
CSA, cUL, EN, UL |
62368-1 |
||
8738 In Stock |
999.00000 |
Active |
Enclosed |
1 |
85 ~ 264 VAC, 120 ~ 370 VDC |
12V |
- |
- |
- |
2.5A |
30 W |
ITE (Commercial), Medical |
Adjustable Output, Universal Input |
-40°C ~ 85°C (With Derating) |
88% |
Through Hole |
5-DIP Module |
2.89" L x 1.50" W x 1.00" H (73.3mm x 38.1mm x 25.4mm) |
CB, CE, cURus, FCC |
- |
||
7032 In Stock |
15.66000 |
Active |
Enclosed |
1 |
85 ~ 264 VAC, 120 ~ 370 VDC |
12V |
- |
- |
- |
250mA |
3 W |
ITE (Commercial) |
Universal Input |
-40°C ~ 85°C |
79% |
Through Hole |
6-DIP Module |
1.13" L x 0.69" W x 0.50" H (28.7mm x 17.5mm x 12.7mm) |
CE, cURus |
- |
||
580 In Stock |
25.64000 |
Active |
Enclosed |
1 |
85 ~ 265 VAC, 120 ~ 370 VDC |
12V |
- |
- |
- |
450mA |
5 W |
ITE (Commercial) |
Universal Input |
-10°C ~ 85°C (With Derating) |
75% |
Through Hole |
4-DIP Module |
1.50" L x 1.00" W x 0.85" H (38.1mm x 25.4mm x 21.5mm) |
CE |
- |
||
20 In Stock |
81.48000 |
Active |
Enclosed |
1 |
90 ~ 264 VAC |
24V |
- |
- |
- |
2.92A |
70 W |
ITE (Commercial) |
Adjustable Output, Universal Input |
-40°C ~ 85°C (With Derating) |
88.5% |
Through Hole |
Half Brick |
2.40" L x 2.28" W x 0.67" H (61.0mm x 57.9mm x 17.0mm) |
CE, cURus, UKCA |
62368-1 |
||
5 In Stock |
243.93000 |
Active |
Enclosed |
3 |
105 ~ 125 VAC |
5V |
15V |
-15V |
- |
1A, 150mA, 150mA |
- |
Medical |
- |
-25°C ~ 71°C |
- |
Through Hole |
7-DIP Module |
3.50" L x 2.50" W x 2.01" H (88.9mm x 63.5mm x 51.0mm) |
CE, cURus |
- |