AC DC Converters
|
|
Mfr Part #
|
Quantity Available
|
Price
|
Product Status
|
Type
|
Number of Outputs
|
Voltage - Input
|
Voltage - Output 1
|
Voltage - Output 2
|
Voltage - Output 3
|
Voltage - Output 4
|
Current - Output (Max)
|
Power (Watts)
|
Applications
|
Features
|
Operating Temperature
|
Efficiency
|
Mounting Type
|
Package / Case
|
Size / Dimension
|
Approval Agency
|
Standard Number
|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
3860 In Stock |
11.93000 |
Active |
Enclosed |
1 |
85 ~ 264 VAC, 100 ~ 370 VDC |
5V |
- |
- |
- |
2.7A |
14 W |
ITE (Commercial) |
Universal Input |
-40°C ~ 70°C (With Derating) |
76% |
Through Hole |
4-DIP Module |
2.12" L x 1.13" W x 0.93" H (53.8mm x 28.8mm x 23.5mm) |
CB Scheme, EN, IEC, UL |
55024; 55032 Class A; 60950-1; 61000-3-2; 62368-1 |
||
90 In Stock |
10.85000 |
Active |
Enclosed |
1 |
85 ~ 305 VAC, 100 ~ 430 VDC |
24V |
- |
- |
- |
450mA |
11 W |
ITE (Commercial) |
- |
-40°C ~ 70°C (With Derating) |
82% |
Through Hole |
4-DIP Module |
2.12" L x 1.13" W x 0.75" H (53.8mm x 28.8mm x 19.0mm) |
CE, cURus |
- |
||
200 In Stock |
14.25000 |
Active |
- |
- |
85 ~ 305 VAC, 120 ~ 430 VDC |
5V |
- |
- |
- |
6A |
- |
- |
- |
- |
77% |
- |
- |
2.44" L x 1.77" W x 0.87" H (62.0mm x 45.0mm x 22.0mm) |
- |
- |
||
21 In Stock |
2.95000 |
Active |
Open Frame |
1 |
85 ~ 305 VAC, 70 ~ 430 VDC |
9V |
- |
- |
- |
333mA |
3 W |
Household Appliances, ITE (Commercial) |
- |
-40°C ~ 85°C (With Derating) |
76% |
Through Hole |
6-SIP Module |
1.04" L x 0.43" W x 0.58" H (26.4mm x 11.0mm x 14.7mm) |
CE, cURus, UL |
60335-1; 62368-1 |
||
4066 In Stock |
8.53000 |
Active |
Enclosed |
1 |
85 ~ 305 VAC, 100 ~ 430 VDC |
24V |
- |
- |
- |
410mA |
9.8 W |
Household Appliances, ITE (Commercial) |
- |
-40°C ~ 85°C (With Derating) |
85% |
Through Hole |
6-DIP Module, 4 Leads |
1.57" L x 1.00" W x 0.83" H (40.0mm x 25.4mm x 21.0mm) |
CE, cURus |
60335-1; 62368-1 |
||
6 In Stock |
206.85000 |
Active |
Enclosed |
1 |
90 ~ 264 VAC |
48V |
- |
- |
- |
2.1A |
100 W |
ITE (Commercial) |
Baseplate, PFC, Universal Input |
-20°C ~ 85°C (With Derating) |
92% |
Through Hole |
5-DIP Module |
4.60" L x 2.40" W x 0.67" H (116.8mm x 61.0mm x 17.0mm) |
CB Scheme, EN, FCC, IEC, UL |
55024; 55032 Class A; 60601-1; 60950-1; 61000-3-2; 61000-3-3; 61000-6-1; 61000-6-2; 61000-6-3; 61204-3 |
||
5544 In Stock |
37.35500 |
Active |
Open Frame |
1 |
85 ~ 264 VAC |
12V |
- |
- |
- |
2.1A |
25 W |
ITE (Commercial) |
Universal Input |
-20°C ~ 70°C (With Derating) |
80% |
Through Hole |
4-DIP Module |
2.96" L x 1.36" W x 1.05" H (75.2mm x 34.6mm x 26.7mm) |
CSA, cUL, EN, IEC, UL |
62368-1 |
||
8107 In Stock |
16.05000 |
Active |
Enclosed |
1 |
90 ~ 264 VAC, 90 ~ 305 VAC, 127 ~ 430 VDC, 127 ~ 370 VDC |
15V |
- |
- |
- |
667mA |
10 W |
Household Appliances, ITE (Commercial) |
Universal Input |
-40°C ~ 70°C (With Derating) |
86% |
Through Hole |
5-SIP Module |
1.46" L x 1.08" W x 0.79" H (37.0mm x 27.5mm x 20.0mm) |
CB, CE, cURus |
60335-1; 62368-1 |
||
200 In Stock |
8.60000 |
Active |
- |
- |
85 ~ 305 VAC, 120 ~ 430 VDC |
12V |
- |
- |
- |
600mA |
- |
- |
- |
- |
68% |
- |
- |
1.65" L x 1.06" W x 0.43" H (41.8mm x 26.9mm x 11.0mm) |
- |
- |
||
8383 In Stock |
22.64000 |
Active |
Open Frame |
1 |
85 ~ 264 VAC |
12V |
- |
- |
- |
410mA |
5 W |
ITE (Commercial) |
Universal Input |
-20°C ~ 70°C (With Derating) |
78% |
Through Hole |
4-DIP Module |
2.00" L x 1.00" W x 0.90" H (50.8mm x 25.4mm x 22.9mm) |
CSA, cUL, EN, IEC, UL |
62368-1 |
||
5801 In Stock |
78.32000 |
Not For New Designs |
Enclosed |
3 |
90 ~ 264 VAC, 100 ~ 375 VDC |
5V |
12V |
-12V |
- |
2A, 200mA, 200mA |
15 W |
Medical |
Universal Input |
-25°C ~ 70°C (With Derating) |
78% |
Through Hole |
9-DIP Module, 7 Leads |
2.52" L x 1.80" W x 0.93" H (64.0mm x 45.6mm x 23.5mm) |
CE, EN, IEC, UL |
60601-1; 60950-1; 62368-1 |
||
45 In Stock |
12.55000 |
Active |
Open Frame |
1 |
80 ~ 275 VAC |
3.3V |
- |
- |
- |
2.3A |
7.6 W |
Medical |
Universal Input |
-20°C ~ 70°C (With Derating) |
70% |
Through Hole |
4-DIP Module |
2.46" L x 1.66" W x 0.91" H (62.5mm x 42.2mm x 23.0mm) |
CB, CE, cTUVus, TUV |
- |
||
15 In Stock |
13.79000 |
Active |
Enclosed |
1 |
85 ~ 305 VAC, 120 ~ 430 VDC |
48V |
- |
- |
- |
630mA |
30 W |
Household Appliances, ITE (Commercial) |
- |
-40°C ~ 85°C (With Derating) |
90% |
Through Hole |
4-DIP Module |
2.74" L x 1.54" W x 0.94" H (69.5mm x 39.0mm x 24.0mm) |
CE, cURus, UKCA |
60335-1; 62368-1 |
||
54 In Stock |
49.76000 |
Obsolete |
Open Frame |
1 |
85 ~ 264 VAC |
18V |
- |
- |
- |
280mA |
5 W |
Medical |
Universal Input |
0°C ~ 70°C (With Derating) |
76% |
Through Hole |
4-DIP Module |
2.17" L x 1.38" W x 0.83" H (55.0mm x 35.0mm x 21.0mm) |
CB Scheme, EN, IEC, UL |
55032 Class A; 60601-1; 60950-1 |
||
6557 In Stock |
29.43000 |
Active |
Enclosed |
1 |
85 ~ 264 VAC |
24V |
- |
- |
- |
210mA |
5 W |
ITE (Commercial) |
Universal Input |
-20°C ~ 70°C (With Derating) |
82% |
Through Hole |
4-DIP Module |
2.06" L x 1.07" W x 0.91" H (52.3mm x 27.2mm x 23.0mm) |
CSA, cUL, EN, IEC, UL |
62368-1 |
||
200 In Stock |
9.50000 |
Active |
- |
- |
85 ~ 305 VAC, 120 ~ 430 VDC |
5V |
- |
- |
- |
- |
- |
- |
- |
- |
80% |
- |
- |
1.89" L x 1.42" W x 0.87" H (48.0mm x 36.0mm x 22.0mm) |
- |
- |
||
29 In Stock |
10.85000 |
Active |
Enclosed |
1 |
85 ~ 305 VAC, 100 ~ 430 VDC |
3.3V |
- |
- |
- |
2A |
6.6 W |
ITE (Commercial) |
- |
-40°C ~ 70°C (With Derating) |
72% |
Through Hole |
4-DIP Module |
2.12" L x 1.13" W x 0.75" H (53.8mm x 28.8mm x 19.0mm) |
CE, cURus |
- |
||
6682 In Stock |
19.93750 |
Active |
Enclosed |
1 |
85 ~ 264 VAC, 120 ~ 370 VDC |
15V |
- |
- |
- |
330mA |
5 W |
ITE (Commercial) |
Universal Input |
-25°C ~ 70°C (With Derating) |
84% |
Through Hole |
5-DIP Module |
1.00" L x 1.00" W x 0.60" H (25.4mm x 25.4mm x 15.2mm) |
CSA, cUL, EN, UL |
62368-1 |
||
9508 In Stock |
193.69000 |
Active |
Enclosed |
1 |
85 ~ 264 VAC |
48V |
- |
- |
- |
6.5A |
300 W |
ITE (Commercial) |
Universal Input |
-40°C ~ 100°C (With Derating) |
90% |
Through Hole |
7-DIP Module |
4.62" L x 2.42" W x 0.50" H (117.3mm x 61.5mm x 12.7mm) |
CE, CSA, cURus, TUV, UL |
60950-1; 62368-1 |
||
200 In Stock |
11.90000 |
Active |
- |
- |
85 ~ 305 VAC, 120 ~ 430 VDC |
5V, 15V |
- |
- |
- |
- |
- |
- |
- |
- |
80% |
- |
- |
2.44" L x 1.77" W x 0.87" H (62.0mm x 45.0mm x 22.0mm) |
- |
- |
||
3 In Stock |
271.09000 |
Active |
Enclosed |
1 |
85 ~ 265 VAC |
28V |
- |
- |
- |
18A |
504 W |
ITE (Commercial) |
Adjustable Output, PFC, PMBus™, Remote On/Off, Remote Sense, Standby Output, Universal Input |
-40°C ~ 100°C (With Derating) |
92% |
Through Hole |
Three Quarter Brick |
4.00" L x 2.40" W x 0.53" H (101.6mm x 61.0mm x 13.5mm) |
CE, cURus, VDE |
- |
||
58 In Stock |
14.90000 |
Active |
Enclosed |
1 |
90 ~ 264 VAC |
48V |
- |
- |
- |
250mA |
12 W |
ITE (Commercial) |
Universal Input |
-20°C ~ 70°C (With Derating) |
82% |
Through Hole |
4-DIP Module |
2.06" L x 1.07" W x 0.91" H (52.4mm x 27.2mm x 23.0mm) |
CB, CE, cURus, UL |
- |
||
48 In Stock |
14.90000 |
Active |
Enclosed |
1 |
90 ~ 264 VAC |
3.3V |
- |
- |
- |
3.01A |
12 W |
ITE (Commercial), Medical |
Universal Input |
-20°C ~ 70°C (With Derating) |
70% |
Through Hole |
6-SIP Module |
2.11" L x 0.92" W x 1.24" H (53.6mm x 23.3mm x 31.5mm) |
CE, cURus, UL |
60601-1; 60950-1 |
||
7 In Stock |
27.82000 |
Active |
Open Frame |
1 |
85 ~ 264 VAC |
24V |
- |
- |
- |
420mA |
10 W |
ITE (Commercial) |
Universal Input |
0°C ~ 60°C (With Derating) |
78% |
Through Hole |
4-DIP Module |
2.56" L x 1.77" W x 0.91" H (65.0mm x 45.0mm x 23.1mm) |
CB Scheme, EN, IEC, SIQ, TUV, UL |
55024; 60950-1; 61000-3-2; 61000-3-3 |