AC DC Converters
|
|
Mfr Part #
|
Quantity Available
|
Price
|
Product Status
|
Type
|
Number of Outputs
|
Voltage - Input
|
Voltage - Output 1
|
Voltage - Output 2
|
Voltage - Output 3
|
Voltage - Output 4
|
Current - Output (Max)
|
Power (Watts)
|
Applications
|
Features
|
Operating Temperature
|
Efficiency
|
Mounting Type
|
Package / Case
|
Size / Dimension
|
Approval Agency
|
Standard Number
|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
7979 In Stock |
18.53800 |
Active |
Enclosed |
1 |
85 ~ 264 VAC, 120 ~ 370 VDC |
9V |
- |
- |
- |
444mA |
4 W |
ITE (Commercial) |
Universal Input |
-25°C ~ 60°C (With Derating) |
75% |
Through Hole |
7-DIP Module, 6 Leads |
1.44" L x 1.06" W x 0.67" H (36.5mm x 27.0mm x 17.1mm) |
CE, UL |
60950-1 |
||
92 In Stock |
17.04000 |
Active |
Enclosed |
1 |
85 ~ 264 VAC, 100 ~ 370 VDC |
48V |
- |
- |
- |
940mA |
45 W |
ITE (Commercial) |
Universal Input |
-40°C ~ 70°C (With Derating) |
87% |
Through Hole |
4-DIP Module |
3.43" L x 2.05" W x 1.16" H (87.0mm x 52.0mm x 29.5mm) |
CE, cURus |
- |
||
7952 In Stock |
999.00000 |
Active |
Enclosed |
1 |
85 ~ 264 VAC, 120 ~ 370 VDC |
18V |
- |
- |
- |
1.67A |
30 W |
ITE (Commercial), Medical |
Adjustable Output, Universal Input |
-40°C ~ 85°C (With Derating) |
88% |
Through Hole |
5-DIP Module |
2.89" L x 1.50" W x 1.00" H (73.3mm x 38.1mm x 25.4mm) |
CB, CE, cURus, FCC |
- |
||
5 In Stock |
33.43000 |
Active |
Open Frame |
1 |
85 ~ 264 VAC, 120 ~ 370 VDC |
5V |
- |
- |
- |
3A |
15 W |
ITE (Commercial), Medical |
Adjustable Output, Universal Input |
-40°C ~ 85°C (With Derating) |
86% |
Through Hole |
5-DIP Module |
1.50" L x 1.00" W x 0.82" H (38.1mm x 25.4mm x 20.8mm) |
CB, CE, cURus, FCC |
- |
||
243 In Stock |
10.78000 |
Active |
Enclosed |
1 |
85 ~ 264 VAC, 100 ~ 370 VDC |
5V |
- |
- |
- |
2A |
10 W |
Household Appliances, ITE (Commercial) |
Universal Input |
-40°C ~ 70°C (With Derating) |
76% |
Through Hole |
4-DIP Module |
2.12" L x 1.13" W x 0.75" H (53.8mm x 28.8mm x 19.0mm) |
CB Scheme, EN, IEC, UL |
55014-1; 55014-2; 55024; 55032 Class A; 60335-1; 60950-1; 61000-3-2; 62368-1 |
||
5378 In Stock |
732.11000 |
Active |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
||
182 In Stock |
12.00000 |
Active |
Open Frame |
1 |
85 ~ 264 VAC, 100 ~ 400 VDC |
12V |
- |
- |
- |
420mA |
5 W |
ITE (Commercial) |
Universal Input |
-25°C ~ 85°C (With Derating) |
76% |
Through Hole, Right Angle |
14-SIP Module, 6 Leads |
1.57" L x 0.79" W x 0.50" H (40.0mm x 20.0mm x 12.8mm) |
CB Scheme, EN, IEC, UL |
55024; 55032 Class A; 60950-1; 62368-1 |
||
8847 In Stock |
36.87200 |
Active |
Open Frame |
1 |
90 ~ 264 VAC |
9V |
- |
- |
- |
6.67A |
60 W |
ITE (Commercial) |
Universal Input |
0°C ~ 70°C (With Derating) |
84% |
Through Hole |
Module |
4.00" L x 2.00" W x 1.27" H (101.6mm x 50.8mm x 32.4mm) |
CE, cURus, FCC, TUV |
62368-1 |
||
200 In Stock |
9.70000 |
Active |
- |
- |
85 ~ 305 VAC, 120 ~ 430 VDC |
12V |
- |
- |
- |
- |
- |
- |
- |
- |
72% |
- |
- |
2.17" L x 1.77" W x 0.87" H (55.0mm x 45.0mm x 22.0mm) |
- |
- |
||
7867 In Stock |
214.93000 |
Active |
Enclosed |
1 |
85 ~ 264 VAC |
28V |
- |
- |
- |
18A |
500 W |
ITE (Commercial) |
Universal Input |
-40°C ~ 100°C (With Derating) |
90% |
Through Hole |
7-DIP Module |
4.62" L x 2.42" W x 0.50" H (117.3mm x 61.5mm x 12.7mm) |
CE, CSA, cURus, TUV, UL |
60950-1; 62368-1 |
||
60 In Stock |
6.60000 |
Active |
Open Frame |
1 |
85 ~ 305 VAC, 100 ~ 430 VDC |
3.3V |
- |
- |
- |
1.6A |
5.28 W |
Household Appliances, ITE (Commercial) |
- |
-40°C ~ 85°C (With Derating) |
70% |
Through Hole, Right Angle |
16-SIP Module, 6 Leads |
1.75" L x 0.88" W x 0.59" H (44.5mm x 22.5mm x 15.0mm) |
CE, cURus |
60335-1; 62368-1 |
||
8668 In Stock |
30.17000 |
Active |
Enclosed |
1 |
85 ~ 264 VAC, 120 ~ 370 VDC |
5V |
- |
- |
- |
5A |
25 W |
ITE (Commercial) |
Universal Input |
-40°C ~ 85°C (With Derating) |
87% |
Through Hole |
6-DIP Module |
1.42" L x 1.00" W x 0.65" H (36.1mm x 25.4mm x 16.5mm) |
CE, cURus |
- |
||
65 In Stock |
170.00000 |
Obsolete |
Enclosed |
1 |
90 ~ 264 VAC |
36V |
- |
- |
- |
2.8A |
101 W |
ITE (Commercial) |
Baseplate, PFC, Universal Input |
-20°C ~ 85°C (With Derating) |
91% |
Through Hole |
Module |
4.60" L x 2.40" W x 0.67" H (116.8mm x 61.0mm x 17.0mm) |
CE, cURus, FCC, TUV |
60950-1 |
||
84 In Stock |
15.09000 |
Active |
Open Frame |
1 |
85 ~ 264 VAC, 120 ~ 370 VDC |
24V |
- |
- |
- |
850mA |
20 W |
ITE (Commercial) |
Universal Input |
-25°C ~ 70°C (With Derating) |
86.06% |
Through Hole |
4-DIP Module |
2.33" L x 1.67" W x 0.90" H (59.2mm x 42.3mm x 22.9mm) |
CB Scheme, EN, FCC, IEC, UL |
60950-1; 61000-3-2; 61000-3-3; 62368-1 |
||
1019 In Stock |
2.95000 |
Active |
Open Frame |
1 |
85 ~ 305 VAC, 70 ~ 430 VDC |
15V |
- |
- |
- |
200mA |
3 W |
Household Appliances, ITE (Commercial) |
- |
-40°C ~ 85°C (With Derating) |
77% |
Through Hole |
6-SIP Module |
1.04" L x 0.43" W x 0.58" H (26.4mm x 11.0mm x 14.7mm) |
CE, cURus, UL |
60335-1; 62368-1 |
||
35 In Stock |
12.70000 |
Obsolete |
Enclosed |
1 |
85 ~ 264 VAC, 100 ~ 400 VDC |
5V |
- |
- |
- |
1A |
5 W |
ITE (Commercial) |
Universal Input |
-25°C ~ 85°C (With Derating) |
70% |
Through Hole |
14-SIP Module, 6 Leads |
1.65" L x 0.98" W x 0.43" H (42.0mm x 25.0mm x 11.0mm) |
cULus |
60950-1 |
||
11 In Stock |
42.22000 |
Active |
Enclosed |
1 |
85 ~ 305 VAC |
9V |
- |
- |
- |
4.44A |
40 W |
Household Appliances, ITE (Commercial) |
- |
-25°C ~ 70°C (With Derating) |
85% |
Through Hole |
4-DIP Module |
3.46" L x 1.50" W x 1.12" H (87.9mm x 38.1mm x 28.5mm) |
CB, TUV, UL |
62368-1 |
||
3 In Stock |
102.96000 |
Active |
Enclosed |
1 |
90 ~ 264 VAC |
24V |
- |
- |
- |
3.12A |
75 W |
ITE (Commercial) |
Baseplate, Universal Input |
-40°C ~ 85°C (With Derating) |
89% |
Through Hole |
Half Brick |
2.40" L x 2.28" W x 0.67" H (61.0mm x 57.9mm x 17.0mm) |
CB, TUV, UL |
62368-1 |
||
8354 In Stock |
999.00000 |
Active |
Enclosed |
1 |
85 ~ 264 VAC, 120 ~ 370 VDC |
9V |
- |
- |
- |
3.34A |
30 W |
ITE (Commercial), Medical |
Adjustable Output, Universal Input |
-40°C ~ 85°C (With Derating) |
88% |
Through Hole |
5-DIP Module |
2.89" L x 1.50" W x 1.00" H (73.3mm x 38.1mm x 25.4mm) |
CB, CE, cURus, FCC |
- |
||
9076 In Stock |
35.79940 |
Active |
Open Frame |
1 |
85 ~ 264 VAC |
24V |
- |
- |
- |
1.1A |
25 W |
ITE (Commercial) |
Adjustable Output, Universal Input |
0°C ~ 70°C (With Derating) |
80% |
Through Hole |
5-DIP Module |
3.35" L x 1.61" W x 0.91" H (85.0mm x 41.0mm x 23.0mm) |
IEC |
60950-1 |
||
81 In Stock |
11.08000 |
Active |
Open Frame |
1 |
90 ~ 264 VAC |
3.3V |
- |
- |
- |
1.25A |
4 W |
ITE (Commercial), Medical |
Universal Input |
-25°C ~ 65°C (With Derating) |
65% |
Through Hole |
6-SIP Module |
1.93" L x 0.51" W x 1.12" H (49.0mm x 13.0mm x 28.5mm) |
CE, cURus, UL |
60601-1; 60950-1 |
||
6507 In Stock |
24.78540 |
Active |
Enclosed |
1 |
90 ~ 264 VAC, 120 ~ 370 VDC |
48V |
- |
- |
- |
520mA |
25 W |
Household Appliances, ITE (Commercial) |
Universal Input |
-30°C ~ 70°C (With Derating) |
87% |
Through Hole |
6-DIP Module |
2.09" L x 1.19" W x 0.98" H (53.1mm x 30.3mm x 24.8mm) |
CB Scheme, EN, IEC, SIQ, TUV, UL |
55024; 55032 Class A; 60950-1; 61000-3-2; 61000-3-3; 61000-6-1; 61000-6-2; 61204-3; 62368-1 |
||
30 In Stock |
44.78000 |
Active |
Open Frame |
3 |
85 ~ 264 VAC |
5V |
12V |
-12V |
- |
2A, 200mA, 200mA |
15 W |
ITE (Commercial) |
Universal Input |
-20°C ~ 70°C (With Derating) |
81% |
Through Hole |
7-DIP Module |
2.44" L x 1.21" W x 0.96" H (62.0mm x 30.7mm x 24.4mm) |
CSA, cUL, EN, IEC, UL |
62368-1 |
||
4144 In Stock |
750.05000 |
Not For New Designs |
Enclosed |
1 |
85 ~ 264 VAC |
24V |
- |
- |
- |
16.67A |
400 W |
ITE (Commercial) |
External Rectification Required, PFC, Universal Input |
-20°C ~ 100°C (With Derating) |
90% |
Through Hole |
4-DIP Module |
4.44" L x 1.40" W x 0.37" H (112.8mm x 35.5mm x 9.3mm) |
CE, cTUVus, cURus |
- |