AC DC Converters
|
|
Mfr Part #
|
Quantity Available
|
Price
|
Product Status
|
Type
|
Number of Outputs
|
Voltage - Input
|
Voltage - Output 1
|
Voltage - Output 2
|
Voltage - Output 3
|
Voltage - Output 4
|
Voltage - Output 5
|
Voltage - Output 6
|
Current - Output 1
|
Current - Output 2
|
Current - Output 3
|
Current - Output 4
|
Current - Output 5
|
Current - Output 6
|
Power (Watts)
|
Applications
|
Voltage - Isolation
|
Efficiency
|
Operating Temperature
|
Features
|
Mounting Type
|
Size / Dimension
|
Approval Agency
|
Standard Number
|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
2697 In Stock |
82.96000 |
Active |
Open Frame |
1 |
85 ~ 264 VAC |
12V |
- |
- |
- |
- |
- |
8.5 A |
- |
- |
- |
- |
- |
- |
ITE (Commercial) |
3 kV |
84.5% |
-10°C ~ 70°C |
- |
Chassis Mount |
6.10" L x 2.44" W x 1.32" H (154.9mm x 62.0mm x 33.5mm) |
CE, CSA, cURus, TUV, UL |
60950-1; 62368-1 |
||
6711 In Stock |
960.01300 |
Active |
Enclosed |
8 |
85 ~ 264 VAC |
24V |
5V |
5V |
24V |
48V |
12V |
8.3 A |
21 A |
6 A |
3 A |
4.17 A |
15 A |
885W |
ITE (Commercial), Medical |
4 kV |
93% |
-40°C ~ 85°C |
Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
Chassis Mount |
10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
CSA, EN, IEC, UL |
60601-1; 60950-1; 62368-1 |
||
8868 In Stock |
950.08700 |
Active |
Enclosed |
7 |
85 ~ 264 VAC |
24V |
5V |
24V |
24V |
24V |
12V |
8.3 A |
21 A |
3 A |
3 A |
8.3 A |
15 A |
1000W |
ITE (Commercial), Medical |
4 kV |
93% |
-40°C ~ 85°C |
Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
Chassis Mount |
10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
CSA, EN, IEC, UL |
60601-1; 60950-1; 62368-1 |
||
4642 In Stock |
603.30000 |
Active |
Enclosed |
4 |
90 ~ 264 VAC, 120 ~ 370 VDC |
5V |
12V |
48V |
5V |
- |
- |
36 A |
20 A |
5 A |
36 A |
- |
- |
840W |
ITE (Commercial), Medical |
4 kV |
88.5% |
-30°C ~ 70°C (With Derating) |
Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input |
Chassis Mount |
9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
CB, CE, cURus, EAC, TUV |
60601-1; 62368-1 |
||
4 In Stock |
1750.00000 |
Active |
Enclosed |
3 |
100 ~ 240 VAC |
5V |
12V |
24V |
- |
- |
- |
3 A |
1.25 A |
625 mA |
- |
- |
- |
45W |
ITE (Commercial) |
- |
- |
0°C ~ 50°C |
Remote On/Off |
Rack Mount |
17.20" L x 1.70" W x 14.10" H (436.9mm x 43.2mm x 358.1mm) |
CE, FCC, UL |
- |
||
2070 In Stock |
969.93900 |
Active |
Enclosed |
9 |
85 ~ 264 VAC |
5V |
24V |
24V |
5V |
24V |
24V |
6 A |
3 A |
8.3 A |
6 A |
3 A |
8.3 A |
825W |
ITE (Commercial), Medical |
4 kV |
93% |
-40°C ~ 85°C |
Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
Chassis Mount |
10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
CSA, EN, IEC, UL |
60601-1; 60950-1; 62368-1 |
||
5815 In Stock |
603.30000 |
Active |
Enclosed |
4 |
90 ~ 264 VAC, 120 ~ 370 VDC |
12V |
24V |
24V |
48V |
- |
- |
20 A |
10 A |
10 A |
5 A |
- |
- |
960W |
ITE (Commercial), Medical |
4 kV |
88.5% |
-30°C ~ 70°C (With Derating) |
Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input |
Chassis Mount |
9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
CB, CE, cURus, EAC, TUV |
60601-1; 62368-1 |
||
4721 In Stock |
853.66000 |
Active |
Enclosed |
6 |
85 ~ 264 VAC |
48V |
48V |
24V |
5V |
24V |
12V |
4.17 A |
4.17 A |
8.3 A |
6 A |
3 A |
15 A |
880W |
ITE (Commercial), Medical |
4 kV |
93% |
-40°C ~ 85°C |
Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
Chassis Mount |
10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
CSA, EN, IEC, UL |
60601-1; 60950-1; 62368-1 |
||
3212 In Stock |
863.58600 |
Active |
Enclosed |
7 |
85 ~ 264 VAC |
48V |
5V |
5V |
24V |
24V |
24V |
4.17 A |
21 A |
6 A |
3 A |
3 A |
3 A |
630W |
ITE (Commercial), Medical |
4 kV |
93% |
-40°C ~ 85°C |
Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
Chassis Mount |
10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
CSA, EN, IEC, UL |
60601-1; 60950-1; 62368-1 |
||
5666 In Stock |
843.73400 |
Active |
Enclosed |
5 |
85 ~ 264 VAC |
5V |
5V |
48V |
24V |
5V |
5V |
21 A |
21 A |
4.17 A |
8.3 A |
21 A |
- |
715W |
ITE (Commercial), Medical |
4 kV |
93% |
-40°C ~ 85°C |
Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
Chassis Mount |
10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
CSA, EN, IEC, UL |
60601-1; 60950-1; 62368-1 |
||
4944 In Stock |
688.27000 |
Active |
Enclosed |
5 |
90 ~ 264 VAC, 120 ~ 370 VDC |
12V |
5V |
5V |
5V |
48V |
- |
20 A |
36 A |
36 A |
36 A |
5 A |
- |
1020W |
ITE (Commercial), Medical |
4 kV |
88.5% |
-30°C ~ 70°C (With Derating) |
Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input |
Chassis Mount |
9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
CB, CE, cURus, EAC, TUV |
60601-1; 62368-1 |
||
8118 In Stock |
969.93900 |
Active |
Enclosed |
9 |
85 ~ 264 VAC |
5V |
24V |
5V |
24V |
24V |
48V |
6 A |
3 A |
21 A |
3 A |
3 A |
4.17 A |
750W |
ITE (Commercial), Medical |
4 kV |
93% |
-40°C ~ 85°C |
Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
Chassis Mount |
10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
CSA, EN, IEC, UL |
60601-1; 60950-1; 62368-1 |
||
4325 In Stock |
688.27000 |
Active |
Enclosed |
5 |
90 ~ 264 VAC, 120 ~ 370 VDC |
5V |
48V |
48V |
24V |
48V |
- |
36 A |
5 A |
5 A |
10 A |
5 A |
- |
1140W |
ITE (Commercial), Medical |
4 kV |
88.5% |
-30°C ~ 70°C (With Derating) |
Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input |
Chassis Mount |
9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
CB, CE, cURus, EAC, TUV |
60601-1; 62368-1 |
||
5731 In Stock |
950.08700 |
Active |
Enclosed |
7 |
85 ~ 264 VAC |
5V |
24V |
48V |
24V |
24V |
24V |
6 A |
3 A |
4.17 A |
8.3 A |
8.3 A |
8.3 A |
1000W |
ITE (Commercial), Medical |
4 kV |
93% |
-40°C ~ 85°C |
Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
Chassis Mount |
10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
CSA, EN, IEC, UL |
60601-1; 60950-1; 62368-1 |
||
1 In Stock |
361.98000 |
Active |
Enclosed |
1 |
90 ~ 264 VAC |
48V |
- |
- |
- |
- |
- |
10.5 A |
- |
- |
- |
- |
- |
504W |
ITE (Commercial), Medical |
4 kV |
91% |
-20°C ~ 80°C (With Derating) |
Adjustable Output, DC Input Capable, PFC, Universal Input |
Chassis Mount |
5.00" L x 3.00" W x 1.38" H (127.0mm x 76.2mm x 35.0mm) |
CE, cURus, DEMKO |
- |
||
9399 In Stock |
853.66000 |
Active |
Enclosed |
6 |
85 ~ 264 VAC |
12V |
5V |
12V |
5V |
24V |
24V |
15 A |
21 A |
15 A |
6 A |
3 A |
8.3 A |
765W |
ITE (Commercial), Medical |
4 kV |
93% |
-40°C ~ 85°C |
Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
Chassis Mount |
10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
CSA, EN, IEC, UL |
60601-1; 60950-1; 62368-1 |
||
5086 In Stock |
434.60530 |
Active |
Open Frame |
- |
85 ~ 264 VAC, 120 ~ 300 VDC |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
Medical |
- |
86% |
-20°C ~ 70°C |
Adjustable Output, Load Sharing, Remote Sense, Universal Input |
Chassis Mount |
5.27" L x 3.06" W x 1.61" H (133.8mm x 77.7mm x 41.0mm) |
CB, CE, CSA, UL |
60601-1 |
||
7776 In Stock |
969.93900 |
Active |
Enclosed |
9 |
85 ~ 264 VAC |
12V |
5V |
24V |
48V |
24V |
24V |
15 A |
6 A |
3 A |
4.17 A |
3 A |
3 A |
880W |
ITE (Commercial), Medical |
4 kV |
93% |
-40°C ~ 85°C |
Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
Chassis Mount |
10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
CSA, EN, IEC, UL |
60601-1; 60950-1; 62368-1 |
||
5635 In Stock |
853.66000 |
Active |
Enclosed |
6 |
85 ~ 264 VAC |
48V |
5V |
24V |
24V |
12V |
24V |
4.17 A |
6 A |
3 A |
8.3 A |
15 A |
8.3 A |
880W |
ITE (Commercial), Medical |
4 kV |
93% |
-40°C ~ 85°C |
Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
Chassis Mount |
10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
CSA, EN, IEC, UL |
60601-1; 60950-1; 62368-1 |
||
1013 In Stock |
430.21130 |
Active |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
||
1319 In Stock |
773.24000 |
Active |
Enclosed |
6 |
90 ~ 264 VAC, 120 ~ 370 VDC |
24V |
24V |
5V |
5V |
48V |
48V |
10 A |
10 A |
36 A |
36 A |
5 A |
5 A |
1200W |
ITE (Commercial), Medical |
4 kV |
88.5% |
-30°C ~ 70°C (With Derating) |
Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input |
Chassis Mount |
9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
CB, CE, cURus, EAC, TUV |
60601-1; 62368-1 |
||
3425 In Stock |
863.58600 |
Active |
Enclosed |
7 |
85 ~ 264 VAC |
24V |
24V |
5V |
48V |
5V |
24V |
3 A |
3 A |
21 A |
4.17 A |
6 A |
3 A |
630W |
ITE (Commercial), Medical |
4 kV |
93% |
-40°C ~ 85°C |
Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
Chassis Mount |
10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
CSA, EN, IEC, UL |
60601-1; 60950-1; 62368-1 |
||
3258 In Stock |
863.58600 |
Active |
Enclosed |
7 |
85 ~ 264 VAC |
24V |
5V |
24V |
24V |
5V |
24V |
8.3 A |
6 A |
3 A |
8.3 A |
6 A |
3 A |
705W |
ITE (Commercial), Medical |
4 kV |
93% |
-40°C ~ 85°C |
Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
Chassis Mount |
10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
CSA, EN, IEC, UL |
60601-1; 60950-1; 62368-1 |
||
4324 In Stock |
853.66000 |
Active |
Enclosed |
6 |
85 ~ 264 VAC |
12V |
5V |
24V |
24V |
48V |
5V |
15 A |
21 A |
3 A |
3 A |
4.17 A |
21 A |
710W |
ITE (Commercial), Medical |
4 kV |
93% |
-40°C ~ 85°C |
Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
Chassis Mount |
10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
CSA, EN, IEC, UL |
60601-1; 60950-1; 62368-1 |