Industrial, DIN Rail Power Supplies
|
|
Mfr Part #
|
Quantity Available
|
Price
|
Product Status
|
Input Type
|
Number of Outputs
|
AC Voltage - Input
|
DC Voltage - Input (Min)
|
DC Voltage - Input (Max)
|
Voltage - Output 1
|
Voltage - Output 2
|
Voltage - Output 3
|
Voltage - Output 4
|
Voltage - Output 5
|
Voltage - Output 6
|
Current - Output (Max)
|
Power (Watts)
|
Voltage - Isolation
|
Applications
|
Efficiency
|
Operating Temperature
|
Features
|
Size / Dimension
|
Approval Agency
|
Standard Number
|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
8369 In Stock |
111.85000 |
Active |
AC |
1 |
115 ~ 230 VAC |
- |
- |
12V |
- |
- |
- |
- |
- |
5.2A |
- |
4.2 kV |
ITE (Commercial) |
- |
-25°C ~ 55°C |
Load Sharing, Universal Input |
2.13" L x 5.67" W x 3.54" H (54.0mm x 144.0mm x 90.0mm) |
cURus, EAC, UL |
- |
||
3351 In Stock |
193.75000 |
Active |
DC |
1 |
- |
18V |
54V |
24V |
- |
- |
- |
- |
- |
76A |
1824W |
500 V |
Industrial |
97% |
-25°C ~ 70°C |
Adjustable Output, IP20 |
6.02" L x 3.27" W x 5.12" H (153.0mm x 83.0mm x 130.0mm) |
CCC, CE, EAC, UL |
UL 508 |
||
2608 In Stock |
1235.15000 |
Active |
AC |
1 |
85 ~ 264 VAC |
- |
- |
24V |
- |
- |
- |
- |
- |
40A |
960W |
4 kV |
ITE (Commercial) |
92% |
-25°C ~ 70°C (With Derating) |
Adjustable Output, IP20, Load Sharing, Universal Input |
4.92" L x 7.09" W x 5.12" H (125.0mm x 180.0mm x 130.0mm) |
CB, cULus, cURus |
- |
||
7 In Stock |
105.03000 |
Active |
AC |
1 |
85 ~ 264 VAC |
- |
- |
5V |
- |
- |
- |
- |
- |
10A |
50W |
3 kV |
ITE (Commercial) |
83% |
-40°C ~ 70°C (With Derating) |
Universal Input |
4.45" L x 1.57" W x 1.12" H (113.0mm x 40.0mm x 28.5mm) |
CB, TUV, UL |
62368-1 |
||
21 In Stock |
42.20000 |
Active |
DC |
1 |
- |
18V |
75V |
24V |
- |
- |
- |
- |
- |
1.25A |
30W |
1.5 kV |
ITE (Commercial) |
87% |
-40°C ~ 80°C (With Derating) |
Adjustable Output, Remote On/Off |
2.99" L x 1.24" W x 0.87" H (76.0mm x 31.5mm x 22.2mm) |
CB Scheme, EN, IEC, UL |
55024; 55032 Class A; 60950-1 |
||
3602 In Stock |
77.59000 |
Active |
DC |
1 |
- |
9V |
36V |
5.1V |
- |
- |
- |
- |
- |
8A |
40W |
- |
ITE (Commercial) |
90% |
-40°C ~ 85°C |
- |
4.41" L x 2.51" W x 1.01" H (112.0mm x 63.8mm x 25.6mm) |
CB, CE, cURus |
62368-1 |
||
5705 In Stock |
166.64000 |
Active |
AC or DC |
1 |
88 ~ 264 VAC |
124V |
370V |
24V |
- |
- |
- |
- |
- |
10A |
240W |
3 kV |
Industrial, ITE (Commercial) |
94% |
-20°C ~ 70°C (With Derating) |
Adjustable Output, PFC, Universal Input |
4.47" L x 2.48" W x 4.93" H (113.5mm x 63.0mm x 125.2mm) |
CB, CE, cULus, cURus |
60950-1; UL 508 |
||
5863 In Stock |
163.44000 |
Active |
AC |
1 |
90 ~ 264 VAC |
- |
- |
24V |
- |
- |
- |
- |
- |
2.5A |
60W |
- |
ITE (Commercial) |
88% |
0°C ~ 70°C (With Derating) |
Adjustable Output, IP20, Universal Input |
3.94" L x 1.77" W x 3.54" H (100.0mm x 45.0mm x 90.0mm) |
CE, cULus, cURus |
60950-1 |
||
4085 In Stock |
137.09000 |
Active |
AC |
1 |
90 ~ 132 VAC, 180 ~ 264 VAC |
- |
- |
48V |
- |
- |
- |
- |
-12V |
5A |
240W |
3 kV |
Hazardous Locations, Industrial, ITE (Commercial) |
90% |
-40°C ~ 70°C (With Derating) |
Adjustable Output, Universal Input |
4.38" L x 3.27" W x 4.92" H (111.3mm x 83.0mm x 125.0mm) |
CE |
62368-1 |
||
5299 In Stock |
38.69060 |
Active |
AC or DC |
1 |
90 ~ 264 VAC |
90V |
375V |
48V |
- |
- |
- |
- |
-12V |
625mA |
30W |
3 kV |
Hazardous Locations, Industrial, ITE (Commercial) |
86% |
-20°C ~ 70°C (With Derating) |
Adjustable Output, Universal Input |
4.53" L x 1.59" W x 3.54" H (115.0mm x 40.5mm x 90.0mm) |
CE |
62368-1 |
||
102 In Stock |
25.83000 |
Active |
AC or DC |
1 |
85 ~ 264 VAC |
120V |
370V |
5V |
- |
- |
- |
- |
- |
6A |
30W |
3 kV |
Hazardous Locations, Industrial, ITE (Commercial) |
78% |
-20°C ~ 70°C (With Derating) |
Adjustable Output, Universal Input |
3.94" L x 1.57" W x 3.54" H (100.0mm x 40.0mm x 90.0mm) |
CB, CE, cULus, cURus, TUV |
- |
||
3724 In Stock |
999.00000 |
Active |
DC |
1 |
- |
18V |
36V |
12V |
- |
- |
- |
- |
- |
2.5A |
30W |
1.6 kV |
ITE (Commercial) |
87% |
-40°C ~ 95°C (With Derating) |
Adjustable Output, Remote On/Off |
4.90" L x 2.27" W x 0.94" H (124.5mm x 57.7mm x 23.9mm) |
CB, CE |
60950-1; 62368-1 |
||
5 In Stock |
44.00000 |
Active |
AC |
1 |
90 ~ 135 VAC, 170 ~ 264 VAC |
- |
- |
24V |
- |
- |
- |
- |
- |
7.5A |
- |
3 kV |
Industrial, ITE (Commercial) |
91% |
-25°C ~ 70°C (With Derating) |
Adjustable Output, Universal Input |
4.13" L x 2.17" W x 4.33" H (105.0mm x 55.0mm x 110.0mm) |
CE |
60950-1; UL 508 |
||
2311 In Stock |
66.67400 |
Active |
DC |
1 |
- |
18V |
75V |
24V |
- |
- |
- |
- |
- |
835mA |
20W |
- |
ITE (Commercial) |
92% |
-40°C ~ 85°C |
- |
3.78" L x 2.13" W x 0.92" H (96.0mm x 54.0mm x 23.3mm) |
CB, CE, cURus |
62368-1 |
||
11 In Stock |
63.25000 |
Active |
AC or DC |
1 |
85 ~ 264 VAC |
100V |
370V |
5V |
- |
- |
- |
- |
- |
2A |
10W |
3 kV |
Hazardous Locations, Industrial, ITE (Commercial) |
77% |
-25°C ~ 75°C (With Derating) |
Adjustable Output, IP20, Universal Input |
3.74" L x 0.89" W x 3.54" H (95.0mm x 22.5mm x 90.0mm) |
CE, cULus, TUV |
62368-1 |
||
1403 In Stock |
101.38770 |
Active |
DC |
1 |
- |
18V |
75V |
48V |
- |
- |
- |
- |
- |
1.56A |
75W |
1.5 kV |
ITE (Commercial) |
84% |
-40°C ~ 100°C (With Derating) |
Adjustable Output, Remote On/Off, Remote Sense |
3.98" L x 2.54" W x 1.03" H (101.2mm x 64.6mm x 26.2mm) |
CE, cURus |
- |
||
8 In Stock |
174.69000 |
Active |
AC |
1 |
350 ~ 575 VAC (3 Phase) |
- |
- |
12V |
- |
- |
- |
- |
- |
10A |
120W |
3.51 kV |
ITE (Commercial), Laboratory |
89.4% |
-25°C ~ 55°C |
Adjustable Output, PFC, Remote On/Off, Remote Sense |
4.87" L x 2.17" W x 5.08" H (123.8mm x 55.2mm x 129.0mm) |
CE |
61010-1;60950-1;62368-1 |
||
8742 In Stock |
109.02000 |
Active |
AC |
1 |
85 ~ 264 VAC |
- |
- |
24V |
- |
- |
- |
- |
- |
1.3A |
30W |
3 V |
ITE (Commercial) |
86% |
-40°C ~ 70°C (With Derating) |
Adjustable Output, PFC, Universal Input |
3.54" L x 1.26" W x 3.54" H (90.0mm x 32.0mm x 90.0mm) |
CE, cULus, cURus, TUV |
- |
||
4 In Stock |
802.12000 |
Active |
AC |
1 |
85 ~ 276 VAC |
- |
- |
36V |
- |
- |
- |
- |
- |
13.3A |
480W |
500 V |
Hazardous Locations, ITE (Commercial) |
94% |
-10°C ~ 70°C (With Derating) |
Adjustable Output, Load Sharing, PFC |
5.00" L x 3.23" W x 4.88" H (127.0mm x 82.0mm x 124.0mm) |
ABS, CSA, DNV GL, EAC, IEC, UL |
Class I Div 2; 508; 60950-1; 61010-2-201 |
||
21 In Stock |
16.42000 |
Active |
AC or DC |
1 |
85 ~ 305 VAC |
100V |
430V |
15V |
- |
- |
- |
- |
- |
200mA |
3W |
4 kV |
Household Appliances, ITE (Commercial) |
79% |
-40°C ~ 85°C (With Derating) |
- |
2.99" L x 1.24" W x 1.22" H (76.0mm x 31.5mm x 31.0mm) |
CE, cURus |
60335-1; 62368-1 |
||
8043 In Stock |
369.28000 |
Active |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
||
8877 In Stock |
225.82000 |
Active |
AC |
1 |
100 ~ 240 VAC |
- |
- |
24V |
- |
- |
- |
- |
- |
3.75A |
90W |
3 kV |
ITE (Commercial) |
80% |
-10°C ~ 60°C (With Derating) |
Adjustable Output, Universal Input |
4.78" L x 1.97" W x 4.53" H (121.3mm x 50.0mm x 115.0mm) |
CE, cULus, cURus, VDE |
- |
||
9310 In Stock |
129.46000 |
Active |
AC or DC |
1 |
85 ~ 264 VAC |
95V |
250V |
5V |
- |
- |
- |
- |
- |
7A |
32W |
4 kV |
ITE (Commercial) |
80% |
-25°C ~ 70°C (With Derating) |
IP20, Load Sharing, Universal Input |
2.40" L x 2.83" W x 3.54" H (61.0mm x 72.0mm x 90.0mm) |
- |
- |
||
9 In Stock |
133.93000 |
Active |
AC |
1 |
100 ~ 480 VAC, 85 ~ 575 VAC |
- |
- |
100 ~ 480V, 85 ~ 575V |
- |
- |
- |
- |
- |
10A |
- |
- |
Hazardous Locations, Industrial, ITE (Commercial) |
- |
-25°C ~ 60°C |
Adjustable Output, IP20 |
3.58" L x 0.89" W x 3.15" H (91.0mm x 22.5mm x 80.0mm) |
CE, CSA, cULus, UL |
60950-1; UL 508 |