Industrial, DIN Rail Power Supplies
|
|
Mfr Part #
|
Quantity Available
|
Price
|
Product Status
|
Input Type
|
Number of Outputs
|
AC Voltage - Input
|
DC Voltage - Input (Min)
|
DC Voltage - Input (Max)
|
Voltage - Output 1
|
Voltage - Output 2
|
Voltage - Output 3
|
Voltage - Output 4
|
Voltage - Output 5
|
Voltage - Output 6
|
Current - Output (Max)
|
Power (Watts)
|
Voltage - Isolation
|
Applications
|
Efficiency
|
Operating Temperature
|
Features
|
Size / Dimension
|
Approval Agency
|
Standard Number
|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1032 In Stock |
887.45000 |
Active |
AC |
1 |
85 ~ 264 VAC |
- |
- |
48V |
- |
- |
- |
- |
- |
10A |
480W |
4 kV |
ITE (Commercial) |
93% |
-25°C ~ 70°C (With Derating) |
Adjustable Output, IP20, Load Sharing, Universal Input |
4.92" L x 3.54" W x 5.12" H (125.0mm x 90.0mm x 130.0mm) |
CB, cULus, cURus |
- |
||
6363 In Stock |
655.23750 |
Active |
DC |
1 |
- |
18V |
75V |
15V |
- |
- |
- |
- |
- |
26.7A |
400W |
- |
- |
- |
-40°C ~ 85°C |
- |
7.83" L x 5.00" W x 2.11" H (198.9mm x 127.0mm x 53.6mm) |
CE |
- |
||
16 In Stock |
64.00000 |
Active |
AC or DC |
1 |
85 ~ 264 VAC |
120V |
375V |
12V |
- |
- |
- |
- |
- |
2A |
24W |
3 kV |
Industrial, ITE (Commercial) |
85% |
-25°C ~ 71°C (With Derating) |
Adjustable Output, IP20, Universal Input |
3.94" L x 0.89" W x 3.60" H (100.0mm x 22.5mm x 90.0mm) |
CE, cULus, TUV |
- |
||
2359 In Stock |
194.98000 |
Active |
AC or DC |
1 |
85 ~ 264 VAC |
120V |
372V |
48V |
- |
- |
- |
- |
- |
2A |
96W |
4.242 kV |
Industrial, ITE (Commercial) |
86% |
-25°C ~ 70°C |
Adjustable Output, IP20, PFC, Universal Input |
4.69" L x 2.05" W x 3.54" H (119.0mm x 52.0mm x 90.0mm) |
cURus, UL |
60950-1; UL 508 |
||
7721 In Stock |
225.82000 |
Active |
AC |
1 |
100 ~ 240 VAC |
- |
- |
24V |
- |
- |
- |
- |
- |
3.75A |
90W |
3 kV |
ITE (Commercial) |
80% |
-10°C ~ 60°C (With Derating) |
Adjustable Output, Universal Input |
4.78" L x 1.97" W x 4.53" H (121.3mm x 50.0mm x 115.0mm) |
CE, cULus, cURus, VDE |
- |
||
9968 In Stock |
29.01000 |
Active |
AC or DC |
1 |
90 ~ 264 VAC |
127V |
370V |
5V |
- |
- |
- |
- |
- |
10A |
50W |
4 kV |
Industrial, ITE (Commercial) |
78% |
-25°C ~ 70°C (With Derating) |
Adjustable Output, Universal Input |
3.85" L x 1.69" W x 4.32" H (97.8mm x 43.0mm x 109.8mm) |
CE, cULus |
62368-1; UL 508 |
||
43 In Stock |
57.39000 |
Active |
AC or DC |
1 |
90 ~ 264 VAC |
127V |
370V |
48V |
- |
- |
- |
- |
- |
1A |
48W |
3 kV |
ITE (Commercial) |
89% |
-25°C ~ 70°C (With Derating) |
Adjustable Output, IP20, Universal Input |
4.04" L x 1.36" W x 4.96" H (102.5mm x 34.5mm x 126.0mm) |
CB Scheme, EN, IEC, SIQ, TUV |
55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3 |
||
5101 In Stock |
50.90000 |
Active |
AC or DC |
1 |
90 ~ 264 VAC |
90V |
375V |
5V |
- |
- |
- |
- |
-12V |
10A |
60W |
3 kV |
Hazardous Locations, Industrial, ITE (Commercial) |
79% |
-20°C ~ 70°C (With Derating) |
Adjustable Output, Universal Input |
4.53" L x 1.59" W x 3.54" H (115.0mm x 40.5mm x 90.0mm) |
CE |
62368-1 |
||
2499 In Stock |
71.65000 |
Active |
AC or DC |
1 |
90 ~ 264 VAC |
120V |
370V |
24V |
- |
- |
- |
- |
- |
3.8A |
100W |
3 kV |
ITE (Commercial) |
89% |
-25°C ~ 71°C (With Derating) |
Adjustable Output, Universal Input |
2.19" L x 3.54" W x 3.58" H (55.6mm x 89.9mm x 90.9mm) |
CE |
- |
||
264 In Stock |
41.10000 |
Active |
DC |
1 |
- |
9V |
36V |
12V |
- |
- |
- |
- |
- |
5A |
60W |
4 kV |
ITE (Commercial) |
91% |
-40°C ~ 85°C (With Derating) |
Adjustable Output |
2.15" L x 2.07" W x 3.54" H (54.5mm x 52.5mm x 90.0mm) |
CE, EAC |
- |
||
19 In Stock |
156.94000 |
Active |
AC |
1 |
85 ~ 264 VAC |
- |
- |
12V |
- |
- |
- |
- |
- |
4A |
50W |
4.3 kV |
ITE (Commercial) |
82% |
-10°C ~ 70°C (With Derating) |
Adjustable Output, Load Sharing, Universal Input |
4.47" L x 1.50" W x 3.54" H (113.6mm x 38.0mm x 90.0mm) |
cCSAus, CE, cULus, NEMKO, TUV |
- |
||
4940 In Stock |
152.00040 |
Active |
AC or DC |
1 |
85 ~ 264 VAC |
120V |
350V |
15V |
- |
- |
- |
- |
- |
6.13A |
92W |
4 kV |
Industrial, ITE (Commercial) |
88% |
-30°C ~ 70°C (With Derating) |
Adjustable Output, IP20, Universal Input |
2.50" L x 2.80" W x 3.60" H (63.5mm x 71.1mm x 91.4mm) |
CE |
62368-1; UL 508 |
||
340 In Stock |
33.07000 |
Active |
DC |
1 |
- |
9V |
36V |
24V |
- |
- |
- |
- |
- |
1.25A |
30W |
4 kV |
ITE (Commercial) |
89% |
-40°C ~ 85°C (With Derating) |
Adjustable Output |
2.15" L x 1.38" W x 3.54" H (54.5mm x 35.0mm x 90.0mm) |
CE, EAC |
- |
||
4328 In Stock |
197.14000 |
Active |
AC or DC |
1 |
90 ~ 305 VAC |
127V |
431V |
24V |
- |
- |
- |
- |
- |
10A |
240W |
4 kV |
ITE (Commercial) |
92% |
-30°C ~ 70°C (With Derating) |
Adjustable Output, PFC, PMBus™ |
5.09" L x 3.37" W x 4.93" H (129.2mm x 85.5mm x 125.2mm) |
CB, CE, cURus, EAC, UKCA |
62368-1 |
||
9062 In Stock |
345.52000 |
Obsolete |
AC |
1 |
330 ~ 550 VAC (3 Phase) |
- |
- |
24V |
- |
- |
- |
- |
- |
25A |
600W |
3 kV |
Industrial, ITE (Commercial) |
92% |
-25°C ~ 70°C (With Derating) |
Adjustable Output |
5.59" L x 3.35" W x 4.88" H (142.0mm x 85.0mm x 124.0mm) |
CE, cULus |
508; 60950-1 |
||
7047 In Stock |
999.00000 |
Active |
DC |
1 |
- |
9.5V |
18V |
3.3V |
- |
- |
- |
- |
- |
5A |
17W |
1.6 kV |
ITE (Commercial) |
83% |
-40°C ~ 92°C (With Derating) |
Adjustable Output, Remote On/Off |
4.90" L x 2.27" W x 0.94" H (124.5mm x 57.7mm x 23.9mm) |
CB, CE |
60950-1 |
||
2329 In Stock |
710.91000 |
Active |
AC or DC |
1 |
320 ~ 550 VAC (3 Phase), 360 ~ 550 VAC (2 Phase) |
226.2V |
390V |
48V |
- |
- |
- |
- |
- |
20A |
960W |
4 kV |
Laboratory |
96.2% |
-25°C ~ 70°C (With Derating) |
Adjustable Output, IP20, PFC, Universal Input |
4.92" L x 4.72" W x 5.12" H (125.0mm x 120.0mm x 130.0mm) |
CB, CSA, UL |
61010-1 |
||
7 In Stock |
695.10000 |
Active |
DC |
1 |
- |
18V |
32V |
24V |
- |
- |
- |
- |
- |
20A |
480W |
4 kV |
Hazardous Locations, ITE (Commercial), Laboratory |
94.7% |
-40°C ~ 70°C (With Derating) |
Adjustable Output, IP20, Remote On/Off |
4.92" L x 2.76" W x 5.12" H (125.0mm x 70.0mm x 130.0mm) |
CB, CSA, cULus, UL |
60950-1; 61010-1; ATEX; IECEx |
||
2762 In Stock |
197.08000 |
Obsolete |
AC or DC |
1 |
90 ~ 132 VAC, 180 ~ 264 VAC |
210V |
375V |
48V |
- |
- |
- |
- |
- |
6.25A |
300W |
3 kV |
Industrial, ITE (Commercial) |
90% |
-30°C ~ 71°C (With Derating) |
Adjustable Output, IP20 |
4.59" L x 3.29" W x 4.90" H (116.6mm x 83.5mm x 124.5mm) |
EN, SIQ, TUV, UL |
508; 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3; 61000-6-2; 61000-6-3; 61204-3; 62368-1 |
||
3 In Stock |
104.46000 |
Active |
AC or DC |
1 |
85 ~ 264 VAC |
90V |
373V |
24V |
- |
- |
- |
- |
- |
2.5A |
60W |
4.242 kV |
Hazardous Locations, ITE (Commercial) |
86% |
-10°C ~ 70°C |
IP20 |
5.35" L x 1.97" W x 3.62" H (136.0mm x 50.0mm x 92.0mm) |
CCC, CE, cURus, UL |
60950-1; 62368-1; ATEX; IECEx |
||
3966 In Stock |
368.59000 |
Last Time Buy |
AC |
1 |
100 ~ 240 VAC |
- |
- |
24V |
- |
- |
- |
- |
- |
4A |
96W |
4 kV |
ITE (Commercial) |
88% |
-25°C ~ 70°C (With Derating) |
Adjustable Output, Load Sharing, PFC, Universal Input |
4.21" L x 2.66" W x 3.90" H (107.0mm x 67.5mm x 99.0mm) |
cULus, cURus |
- |
||
4029 In Stock |
17.94810 |
Obsolete |
AC or DC |
1 |
85 ~ 264 VAC |
100V |
370V |
5V |
- |
- |
- |
- |
- |
1A |
5W |
4 kV |
ITE (Commercial) |
75% |
-40°C ~ 70°C (With Derating) |
Universal Input |
2.99" L x 1.24" W x 1.24" H (76.0mm x 31.5mm x 31.4mm) |
CB Scheme, EN, IEC, UL |
55024; 55032 Class A; 60950-1; 61000-3-2; 62368-1 |
||
8995 In Stock |
336.98000 |
Active |
AC |
1 |
85 ~ 264 VAC |
- |
- |
24V |
- |
- |
- |
- |
- |
20A |
480W |
- |
ITE (Commercial) |
94% |
-25°C ~ 70°C (With Derating) |
Adjustable Output, IP20, Universal Input |
5.38" L x 2.56" W x 5.14" H (136.7mm x 65.0mm x 130.5mm) |
CE, cULus, cURus |
- |
||
6345 In Stock |
999.00000 |
Active |
DC |
1 |
- |
9.5V |
18V |
24V |
- |
- |
- |
- |
- |
1.8A |
43W |
1.6 kV |
ITE (Commercial) |
83% |
-40°C ~ 97°C (With Derating) |
Adjustable Output, Remote On/Off |
4.90" L x 2.27" W x 0.94" H (124.5mm x 57.7mm x 23.9mm) |
CE |
60950-1; 62368-1 |